Step 1: Select your system or products:

Search
Selected Systems
Undo

Showing 121 - 130 of 308 Systems Available

F-A-2190

F-A-2190

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
Special Conditions
Floor and Shower Drains
F-A-2221

F-A-2221

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
  • Equal F&T
F-A-2269

F-A-2269

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
F-A-2297

F-A-2297

UL Ratings F (Flame): 1-Hour or 2-Hour. Equal F&T.
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
United States (UL)
System Barrier Type
Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • Equal F&T
F-A-2298

F-A-2298

UL Ratings F (Flame): 1-Hour or 2-Hour. W (Water Tightness).
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
United States (UL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • W (Water Tightness)
F-A-2299

F-A-2299

UL Ratings F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
United States (UL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
F-A-2300

F-A-2300

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). Equal F&T.
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
United States (UL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
  • Equal F&T
F-A-2301

F-A-2301

UL Ratings F (Flame): 1-Hour or 2-Hour. Equal F&T.
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
United States (UL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • Equal F&T
F-A-2303

F-A-2303

UL Ratings F (Flame): 1-Hour or 2-Hour. Equal F&T.
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • Equal F&T
Image
Concrete texture

Engineering Judgement

Submit an Engineering Judgement request for code-compliant solutions from a HoldRite Firestop Specialist