C-AJ-8304

C-AJ-8304

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Multiple Penetration

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Multiple Penetration
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
C-AJ-8311

C-AJ-8311

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour
Penetrant/Pipe Material
Multiple Penetration

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Multiple Penetration
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
F-A-0026

F-A-0026

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Blank Openings

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck
Penetrant/Pipe Material
Blank Openings
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
  • Equal F&T
F-A-0042

F-A-0042

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Blank Openings

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Blank Openings
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
  • Equal F&T
F-A-0043

F-A-0043

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Blank Openings

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck
Penetrant/Pipe Material
Blank Openings
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
  • Equal F&T
F-A-1103

F-A-1103

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Metallic Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Metallic Pipes
Associated Products
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
Special Conditions
Tub Box
F-A-1109

F-A-1109

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Metallic Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Metallic Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
Special Conditions
Closet Flange
F-A-1111

F-A-1111

UL Ratings F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Metallic Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Metallic Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
Special Conditions
Floor and Shower Drains
F-A-1122

F-A-1122

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Metallic Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck
Penetrant/Pipe Material
Metallic Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
F-A-1133

F-A-1133

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Metallic Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Metallic Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
  • Equal F&T
Image
Concrete texture

Engineering Judgement