C-AJ-8304
UL Ratings
F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Multiple Penetration
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Multiple Penetration
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- L (Air/Smoke Leakage)
- W (Water Tightness)
C-AJ-8311
UL Ratings
F (Flame): 1-Hour or 2-Hour or 3-Hour
Penetrant/Pipe Material
Multiple Penetration
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Multiple Penetration
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- 3-Hour
F-A-0026
UL Ratings
F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Blank Openings
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck
Penetrant/Pipe Material
Blank Openings
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- L (Air/Smoke Leakage)
- W (Water Tightness)
- Equal F&T
F-A-0042
UL Ratings
F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Blank Openings
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Blank Openings
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- L (Air/Smoke Leakage)
- W (Water Tightness)
- Equal F&T
F-A-0043
UL Ratings
F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Blank Openings
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck
Penetrant/Pipe Material
Blank Openings
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- L (Air/Smoke Leakage)
- W (Water Tightness)
- Equal F&T
F-A-1103
UL Ratings
F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Metallic Pipes
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Metallic Pipes
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- 3-Hour
- L (Air/Smoke Leakage)
- W (Water Tightness)
Special Conditions
Tub Box
F-A-1109
UL Ratings
F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Metallic Pipes
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Metallic Pipes
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- 3-Hour
- L (Air/Smoke Leakage)
- W (Water Tightness)
Special Conditions
Closet Flange
F-A-1111
UL Ratings
F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Metallic Pipes
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Metallic Pipes
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
Special Conditions
Floor and Shower Drains
F-A-1122
UL Ratings
F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Metallic Pipes
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck
Penetrant/Pipe Material
Metallic Pipes
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- L (Air/Smoke Leakage)
- W (Water Tightness)
F-A-1133
UL Ratings
F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Metallic Pipes
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Metallic Pipes
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- 3-Hour
- L (Air/Smoke Leakage)
- W (Water Tightness)
- Equal F&T