Welcome to RWC’s Firestop System Search & Submittals
HoldRite’s HydroFlame Firestop Solutions Submittal Generator makes compiling a submittal package for HoldRite Firestop Solutions fast and easy. To access our Commercial Submittal Pack or our Acoustical Isolation Submittal Pack visit our Submittal Packs page.
Step 1: Select your system or products:
Showing 91 - 100 of 308 Systems Available
C-AJ-7224
UL Ratings
F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
C-AJ-8291
UL Ratings
F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Multiple Penetration
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Multiple Penetration
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
C-AJ-8292
UL Ratings
F (Flame): 1-Hour or 2-Hour or 3-Hour
Penetrant/Pipe Material
Multiple Penetration
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Multiple Penetration
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- 3-Hour
C-AJ-8293
UL Ratings
F (Flame): 1-Hour or 2-Hour. Equal F&T.
Penetrant/Pipe Material
Multiple Penetration
System Properties:
Testing Authorities
United States (UL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Multiple Penetration
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- Equal F&T
C-AJ-8294
UL Ratings
F (Flame): 1-Hour or 2-Hour. Equal F&T.
Penetrant/Pipe Material
Multiple Penetration
System Properties:
Testing Authorities
United States (UL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Multiple Penetration
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- Equal F&T
C-AJ-8295
UL Ratings
F (Flame): 1-Hour or 2-Hour. Equal F&T.
Penetrant/Pipe Material
Multiple Penetration
System Properties:
Testing Authorities
United States (UL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Multiple Penetration
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- Equal F&T
C-AJ-8296
UL Ratings
F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets), Multiple Penetration
System Properties:
Testing Authorities
United States (UL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets), Multiple Penetration
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
C-AJ-8297
UL Ratings
F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage).
Penetrant/Pipe Material
Multiple Penetration
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Multiple Penetration
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- L (Air/Smoke Leakage)
C-AJ-8298
UL Ratings
F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets), Multiple Penetration
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets), Multiple Penetration
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- L (Air/Smoke Leakage)
- W (Water Tightness)
C-AJ-8299
UL Ratings
F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Multiple Penetration
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Multiple Penetration
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- L (Air/Smoke Leakage)
- W (Water Tightness)