Skip to main content
Image
Contractor using tools to install firestopping devices.

Firestop Submittal Generator

Welcome to RWC’s Firestop System Search & Submittals

HoldRite’s HydroFlame Firestop Solutions Submittal Generator makes compiling a submittal package for HoldRite Firestop Solutions fast and easy. To access our Commercial Submittal Pack or our Acoustical Isolation Submittal Pack visit our Submittal Packs page.

Step 1: Select your system or products:

Search
Selected Systems
Undo

Showing 71 - 80 of 308 Systems Available

C-AJ-5414

C-AJ-5414

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage).
Penetrant/Pipe Material
Insulated Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Insulated Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
C-AJ-5426

C-AJ-5426

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour
Penetrant/Pipe Material
Insulated Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Insulated Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
C-AJ-5428

C-AJ-5428

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour
Penetrant/Pipe Material
Insulated Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Insulated Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
C-AJ-5429

C-AJ-5429

UL Ratings F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Insulated Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Insulated Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
C-AJ-5431

C-AJ-5431

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. Equal F&T.
Penetrant/Pipe Material
Insulated Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Insulated Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • Equal F&T
C-AJ-5433

C-AJ-5433

UL Ratings F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Insulated Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Insulated Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
Image
Concrete texture

Engineering Judgement

Submit an Engineering Judgement request for code-compliant solutions from a HoldRite Firestop Specialist