Skip to main content
Image
Contractor using tools to install firestopping devices.

Firestop Submittal Generator

Welcome to RWC’s Firestop System Search & Submittals

HoldRite’s HydroFlame Firestop Solutions Submittal Generator makes compiling a submittal package for HoldRite Firestop Solutions fast and easy. To access our Commercial Submittal Pack or our Acoustical Isolation Submittal Pack visit our Submittal Packs page.

Step 1: Select your system or products:

Search
Selected Systems
Undo

Showing 61 - 70 of 308 Systems Available

C-AJ-3369

C-AJ-3369

UL Ratings F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Cables

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Cables
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
C-AJ-3375

C-AJ-3375

UL Ratings F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Cables

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Cables
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
C-AJ-5408

C-AJ-5408

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage).
Penetrant/Pipe Material
Insulated Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Insulated Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
C-AJ-5409

C-AJ-5409

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage).
Penetrant/Pipe Material
Insulated Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Insulated Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
C-AJ-5410

C-AJ-5410

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage).
Penetrant/Pipe Material
Insulated Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Insulated Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
C-AJ-5412

C-AJ-5412

UL Ratings F (Flame): 1-Hour
Penetrant/Pipe Material
Insulated Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Insulated Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
Image
Concrete texture

Engineering Judgement

Submit an Engineering Judgement request for code-compliant solutions from a HoldRite Firestop Specialist