Showing 111 - 120 of 308 Systems Available

F-A-1187

F-A-1187

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Metallic Pipes

System Properties:

Testing Authorities
United States (UL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Metallic Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
F-A-1189

F-A-1189

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Metallic Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck
Penetrant/Pipe Material
Metallic Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
Special Conditions
Testrite Test Tee
F-A-1190

F-A-1190

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Metallic Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Metallic Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
Special Conditions
Testrite Test Tee
F-A-1191

F-A-1191

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Metallic Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck
Penetrant/Pipe Material
Metallic Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
Special Conditions
Testrite Test Tee
F-A-1200

F-A-1200

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Metallic Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Metallic Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
F-A-1201

F-A-1201

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Metallic Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck
Penetrant/Pipe Material
Metallic Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
F-A-1206

F-A-1206

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Metallic Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Metallic Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
F-A-2183

F-A-2183

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Non-Metallic
Associated Products
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
Special Conditions
Tub Box
F-A-2189

F-A-2189

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
  • Equal F&T
Special Conditions
Closet Flange
Image
Concrete texture

Engineering Judgement

Submit an Engineering Judgement request for code-compliant solutions from a HoldRite Firestop Specialist