F-A-2304
UL Ratings
F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Non-Metallic
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Non-Metallic
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
F-A-2305
UL Ratings
F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Non-Metallic
System Properties:
Testing Authorities
United States (UL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Non-Metallic
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
F-A-2306
UL Ratings
F (Flame): 1-Hour or 2-Hour. Equal F&T.
Penetrant/Pipe Material
Non-Metallic
System Properties:
Testing Authorities
United States (UL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Non-Metallic
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- Equal F&T
F-A-2319
UL Ratings
F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Non-Metallic
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Non-Metallic
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
F-A-2320
UL Ratings
F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Non-Metallic
System Properties:
Testing Authorities
United States (UL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Non-Metallic
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
F-A-2367
UL Ratings
F (Flame): 1-Hour or 2-Hour or 3-Hour
Penetrant/Pipe Material
Multiple Penetration, Non-Metallic
System Properties:
Testing Authorities
United States (UL)
System Barrier Type
Concrete Floors Flat Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Multiple Penetration, Non-Metallic
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- 3-Hour
F-A-2368
UL Ratings
F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Non-Metallic
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- 3-Hour
- L (Air/Smoke Leakage)
- W (Water Tightness)
- Equal F&T
F-A-3052
UL Ratings
F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Cables
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Cables
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- 3-Hour
- L (Air/Smoke Leakage)
- W (Water Tightness)
Special Conditions
Cable Chase
F-A-3080
UL Ratings
F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Cables
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Cables
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- 3-Hour
- L (Air/Smoke Leakage)
- W (Water Tightness)
- Equal F&T
F-A-5043
UL Ratings
F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Insulated Pipes
System Properties:
Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck, Minimum 2-1/2 inch concrete floor
Penetrant/Pipe Material
Insulated Pipes
Associated Products
UL Ratings:
- F (Flame)
- 1-Hour
- 2-Hour
- 3-Hour
- L (Air/Smoke Leakage)
- W (Water Tightness)