F-B-1039

F-B-1039

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Metallic Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Minimum 6 inch Concrete Floors Flat Deck
Penetrant/Pipe Material
Metallic Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
F-B-2042

F-B-2042

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
United States (UL)
System Barrier Type
Concrete Floors Flat Deck, Corrugated Metal Form Deck
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
  • Equal F&T
F-B-2042 drawing Canada

F-B-2042

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Non-Metallic

System Properties:

UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
  • Equal F&T
F-B-2043

F-B-2043

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). T (Temperature). W (Water Tightness).
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Minimum 6 inch Concrete Floors Flat Deck
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • T (Temperature)
  • W (Water Tightness)
Special Conditions
Tub Box
F-B-2072

F-B-2072

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). T (Temperature). W (Water Tightness).
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
United States (UL)
System Barrier Type
Minimum 6 inch Concrete Floors Flat Deck
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • T (Temperature)
  • W (Water Tightness)
xhez7 f-b-2072 canada

F-B-2072

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). Equal F&T.
Penetrant/Pipe Material
Non-Metallic

System Properties:

Testing Authorities
Canada (ULC/cUL)
System Barrier Type
Minimum 6 inch Concrete Floors Flat Deck
Penetrant/Pipe Material
Non-Metallic
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • Equal F&T
F-B-5013

F-B-5013

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Insulated Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Minimum 6 inch Concrete Floors Flat Deck
Penetrant/Pipe Material
Insulated Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
F-B-8013

F-B-8013

UL Ratings F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
F-B-8016

F-B-8016

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). T (Temperature). W (Water Tightness). Equal F&T.
Penetrant/Pipe Material
Multiple Penetration

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Minimum 6 inch Concrete Floors Flat Deck
Penetrant/Pipe Material
Multiple Penetration
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • T (Temperature)
  • W (Water Tightness)
  • Equal F&T