C-AJ-5434

C-AJ-5434

UL Ratings F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Insulated Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Insulated Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
C-AJ-5435

C-AJ-5435

UL Ratings F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Insulated Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Insulated Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
C-AJ-5436

C-AJ-5436

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour
Penetrant/Pipe Material
Insulated Pipes

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Insulated Pipes
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
C-AJ-7202

C-AJ-7202

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage).
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
C-AJ-7203

C-AJ-7203

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage).
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
C-AJ-7204

C-AJ-7204

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage).
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
C-AJ-7205

C-AJ-7205

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage).
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
C-AJ-7206

C-AJ-7206

UL Ratings F (Flame): 1-Hour or 2-Hour. L (Air/Smoke Leakage).
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
  • L (Air/Smoke Leakage)
C-AJ-7209

C-AJ-7209

UL Ratings F (Flame): 1-Hour or 2-Hour or 3-Hour. L (Air/Smoke Leakage). W (Water Tightness).
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
    • 3-Hour
  • L (Air/Smoke Leakage)
  • W (Water Tightness)
C-AJ-7222

C-AJ-7222

UL Ratings F (Flame): 1-Hour or 2-Hour
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)

System Properties:

Testing Authorities
United States (UL), Canada (ULC/cUL)
System Barrier Type
Concrete Floors Flat Deck, Concrete or Masonry Block Wall
Penetrant/Pipe Material
Misc Mechanical (Duct/Line Sets)
UL Ratings:
  • F (Flame)
    • 1-Hour
    • 2-Hour
Image
Concrete texture

Engineering Judgement

Submit an Engineering Judgement request for code-compliant solutions from a HoldRite Firestop Specialist